Test items
Test the DC internal
resistance of batteries.
System
characteristics
1. The DCIR
tester automatically tests the DC internal resistance of each single battery on
the incoming battery tray, turns into a production management control system to
automatically accomplish the binding of production data information and
auto-saving, and transmits the data externally through network connections.
2. The DCIR
tester, developed independently by our company which owns complete intellectual
property rights, features high test precision, high reliability and stability, and
can integrate seamlessly with automatic logistics equipment and technological
equipment for the prior and next processes.
3. Embedded
design is employed for the human-machine interface; the height of the display
and operating platform meets the ergonomics requirements; the machine,
featuring self-testing software and database system is easy to operate,
reliable and stable.
Functional
characteristics
1. Based on the
principle of BSEN61960, the evaluation method of DCIR adopts the two-stage
load current test and calculates the DCIR value based on the voltage difference
caused by the current change, which is closer to the actual resistance effect
of continuous battery current application. Therefore, power battery or
high-power energy type battery can be evaluated for the DCIR characteristics.
2. The power
cabinet tester, with the switching response time shorter less than 15ms and
pulse width shorter than 100 ms, can instantly capture small change curve of
current and voltage, providing an accurate and high precision test hardware
platform for testing the DCIR of batteries. The software algorithm, developed
in accordance with the HPPC standard test method, is approximate to the
performance characteristics of the battery itself.
3. Due to the
use of an alloy probe as the contact probe, the contact impedance is less than
one half of that for similar probe of beryllium copper. In high temperature
environment of 45℃,
the overflow temperature rise for large current is less than 6℃.
4. Conduct shock
test on battery with large current, calculate the DC
internal resistance by dividing the voltage difference by the current
difference, and the DCIR tester can screen out some batteries with damaged
diaphragms in advance.
Test method
A. DC internal
resistance in discharging
a1. 80 A
constant current, discharge for 10s [take voltage Vd0 in the 9th second]
a2. 150A
constant current, discharge for 10s [take voltage Vd1 in the 1st second]
Stabilize for 20s
B. DC resistance
in charging
a1. 80A constant
current, charging for 10s [take voltage Vc0 in the 9th second]
a2. 150A
constant current, charging 10s [take voltage Vc1 in the 1st second]
Stop
Equipment parameters